[email protected] +91 9840521421 Scholarly Open Access, Peer-reviewed, Refereed Journal e-ISSN 2583-5300 Since 2022
  1. Home
  2. Archives
  3. 2026
  4. Vol. 5 Issue 2
  5. Article
Original Article

Evaluation of Diagnostic Accuracy of Open-Source and Proprietary Large Language Models Across Multi-System Clinical Cases

Open Access Peer Reviewed Crossref DOI

Authors

  • Saurabh Lalwani1
  • Dr. Vishala Bodetti2
  • Kishan Gor3
  • Nrip Nihalani4
  • Aditya Patkar5

1 2 3 4 5 Plus91 Technologies Pvt. Ltd., Pune, Maharashtra, India.

Article Information

Published Online
May-August 2026
Pages
997-1004
Article Type
Original Article
Check for updates
check update

Abstract

View PDF

Large language models show potential for clinical diagnostic support, but their diagnostic accuracy across diverse real-world patient presentations remains uncertain. We evaluated diagnostic retrieval and ranking using multi-system emergency-department narratives from MIMIC-IV-Ext version 1.0.2, a deidentified research dataset derived from MIMIC-IV and curated for research involving referral, triage and diagnostic prediction. The dataset was selected because it links early clinical information, including presenting complaints, history and initial vital signs, with documented diagnoses derived from routine care. A locked cohort of 995 diagnosis-free vignettes was used, with one protected index primary diagnosis per case. GPT-5.6 Thinking, Claude Sonnet 5, Llama-3.1-8B-Instruct and Mistral-7B-Instruct-v0.3 independently generated exactly three ranked differential diagnoses for every vignette. The principal outcome was concept-equivalent Top-3 accuracy; Top-1 accuracy, mean reciprocal rank, omission rate, strict text matching, system-wise performance and paired statistical comparisons were secondary outcomes. GPT-5.6 achieved the highest Top-1 accuracy (41.7%), Top-3 accuracy (61.1%) and mean reciprocal rank (0.504). Claude ranked second at 39.8%, 55.3% and 0.467, respectively. Llama reached 25.5% Top-1 and 41.3% Top-3 accuracy, while Mistral reached 22.8% and 38.7%. Overall Top-3 outcomes differed significantly across models (Cochran Q=271.73, df=3, p=1.31×10⁻⁵⁸). Under identical clinical inputs and scoring rules, the proprietary models retrieved the documented index diagnosis more often and ranked it higher than the two open-weight models. These findings provide a reproducible estimate of diagnostic retrieval accuracy across four widely used model configurations and establish a baseline for further clinical validation.

APC from ₹1200 + 18% GST

Peer-reviewed open access₹1200 Indian (₹1400 with DOI)$80 USD internationalpaid after acceptance Peer-reviewed open access₹1200 Indian$80 USD international ₹1200 Indian · $80 intl

  • CrossRef DOI
  • ISSN 2583-5300
  • Open Access
  • Peer Reviewed
  • Plagiarism Checked
  • Google Scholar
Submit Paper