Is Spare Capacity Worth Its Embodied Carbon? Distributionally Robust Capacity Planning for Carbon-Aware Cloud Data Centers under Grid-Decarbonization Uncertainty

Open Access Peer Reviewed Crossref DOI

Authors

  • Harshal D1

1 K J Somaiya College of Science and Commerce, Mumbai, Maharashtra, India.

Article Information

Published Online
September-December 2026
Pages
906-911
Article Type
Original Article
Check for updates
check update

Abstract

View PDF

Carbon-aware scheduling shifts flexible work into hours when the grid is cleaner, but it can only do so if servers are idle at those hours, so most evaluations implicitly assume that spare capacity exists. Spare servers are not free: their manufacturing (embodied) emissions are incurred at purchase, while the operational savings they enable accrue over a lifetime whose length is uncertain, against grids whose future carbon intensity is uncertain too. We formulate the decision of how much spare capacity to build, and where, as a two-stage distributionally robust program. The first stage chooses slack in each region and pays its embodied carbon; the second stage, for every operating year and decarbonization pathway, solves a linear program that shifts flexible load into low-carbon hours subject to capacity and idle power. Ambiguity over pathways and server lifetimes is a total-variation ball around nominal scenario weights, and the inner supremum is dualized so that the whole problem is one linear program. We show that each scenario’s incremental carbon is convex in the slack vector and give a break-even condition comparing embodied intensity with the worst-case expected marginal operational savings. On a four-region, 100 MW case study, the 1.7× load provisioning assumed in prior carbon-aware scheduling studies adds 68 kt CO₂e over the hardware lifetime, because the embodied carbon of 44.5 MW of extra servers is never recovered. The stochastic optimum builds 4.7 MW of slack in the solar-rich region only, with an expected lifetime saving of just 0.6 kt, and the robust optimum builds none once the ambiguity radius reaches 0.25. Spare capacity pays robustly only for low-embodied hardware (≤ 1,000 t CO₂e per MW), which points to server reuse and burst capacity as the carbon-efficient source of scheduling slack.

APC from ₹1200 + 18% GST

Peer-reviewed open access₹1200 Indian (₹1400 with DOI)$80 USD internationalpaid after acceptance Peer-reviewed open access₹1200 Indian$80 USD international ₹1200 Indian · $80 intl

  • CrossRef DOI
  • ISSN 2583-5300
  • Open Access
  • Peer Reviewed
  • Plagiarism Checked
  • Google Scholar
Contact Us Submit Paper